Instruction Manual for 50-Meter Dust-Capturing Mist Fog Cannon

The working principle of the 50-meter dust-capturing mist fog cannon is based on the synergy of hydraulics, aerodynamics, and electronic control systems. It relies on key components like high-pressure water pumps, precision nozzles, and intelligent control systems to achieve effective dust reduction. Below, the editor from Zhengtong Mist Fog Cannon will help you understand the instruction manual for the 50-meter dust-capturing mist fog cannon in 3 minutes.

Instruction Manual for 50-Meter Dust-Capturing Mist Fog Cannon

Preparation for Operation

Check power and water supply: Ensure the generator set or main power supply provides stable power at 380V voltage and 50Hz frequency. A well-grounded power switch should be installed in front of the electrical control box when connecting three-phase 380V power.

Wear protective gear: Operators must wear safety protective equipment such as work clothes, masks, and goggles to ensure safety.

Installation and Commissioning

Installation location: Select the appropriate mist fog cannon model and installation position based on the dust-reduction site, ensuring the spray range covers the target area.

Connect water supply: Use a dedicated spray valve to connect the water inlet of the mist fog cannon and the water outlet of the water tank, ensuring firm pipe connections without leakage.

Startup and Operation

Start the machine: First turn on the power switch, start the generator set or connect the main power. After the equipment is preheated, gradually start the fan and water pump.

Adjust spray: Set the spray angle, range, and intensity via the control panel to achieve the best dust-capturing effect. Regularly check the spray effect during operation; if unevenness or inadequacy is found, adjust the nozzles or related parameters in time.

Instruction Manual for 50-Meter Dust-Capturing Mist Fog Cannon

Safety Precautions

Prevent injury from spray: Never point the nozzles at people or animals to avoid accidental injury from high-pressure water mist. Meanwhile, test runs after mist fog cannon maintenance should be conducted in enclosed areas, and only short-term high-speed test runs are allowed.

Keep equipment stable: Maintain a steady working posture during operation, operate smoothly to avoid accidents. Check for loose materials near the work area (a practice called “roof and rib inspection” in construction) and remove them to prevent falls or other injuries.

Maintenance

Regular inspection: Periodically check the water pump pressure and nozzle atomization effect to ensure normal equipment operation. Also, conduct regular safety checks on air hoses, joints, clamps, and other components; repair or replace them promptly if abnormalities are found.

Cleaning and lubrication: After operation, turn off the mist fog cannon and clean it immediately—especially the nozzles and filters—to prevent clogging. Regularly add oil and lubricate the equipment’s lubrication points to reduce wear and extend service life.

Instruction Manual for 50-Meter Dust-Capturing Mist Fog Cannon

In general, the 50-meter dust-capturing mist fog cannon not only effectively reduces dust concentration and improves the working environment but also has advantages like energy efficiency, environmental protection, and easy operation and maintenance. It is an ideal dust-reduction equipment. Proper operation of the mist fog cannon can effectively improve operational efficiency and extend its service life.